Flow totalizer

DP Level & Flow

What this tool does

Rate and total from a pulse K-factor, plus the linear current that rate would drive. This page says what the tool is for, in plain language. The working formula stays on the signed-in tool.

When to use it

Open Flow totalizer when this is the job: Rate and total from a pulse K-factor, plus the linear current that rate would drive. That is usually a level or flow calibration, a bore check, or a valve you are about to size.

Step-by-step

  1. Open Flow totalizer from the tool list.
  2. Fill Units, K-factor, Frequency, Frequency span from the instrument, the drawing, or the job record. Use the unit shown beside each field.
  3. Fill the remaining fields the same way. Skip a field only when the screen marks it optional.
  4. Run Calculate when that control is on the page, then read every result row and any warning.
  5. Check the result against the site procedure and the manufacturer data before you change a range, a wire, a setpoint, or a weight.
  6. This help page is public. Opening the tool still requires a Pro session.

Inputs

Units
Imperial or metric. Pick one and enter every other field in that system.
K-factor
Pulses per unit volume from the flowmeter sheet.
Frequency
The pulse rate you are measuring.
Frequency span
Frequency span is the value you read from the instrument, the drawing, or the job record. Enter it in Hz.
Pulse count
Pulse count is the value you read from the instrument, the drawing, or the job record.
Rate LRV
Rate LRV is the value you read from the instrument, the drawing, or the job record.
Rate URV
Rate URV is the value you read from the instrument, the drawing, or the job record.

Results

Result
The reported value for Flow totalizer. Use the unit printed on that row.
Warnings
A warning means an entry is incomplete or outside what this tool will stand behind. Recheck the inputs and the site procedure.

Common mistakes

  • Using the wrong specific gravity, or forgetting a wet leg, a seal fill, or a blanket pressure.
  • Mixing a head unit with a pressure unit without reading the unit on the screen.
  • Sizing from a flow or a differential that is not the one in the line.
  • Do not treat a result from Flow totalizer as a substitute for the site procedure or the manufacturer data.

Standards references

These are the standards and public references named on this tool. Clause numbers appear only when the catalog already cites them.

  • Pulse K-factor, pulses per unit volume
  • ISA linear analog span on the resulting rate
  • US gallon of 231 in³

Offline and access

This engine can run offline after the server has cached it for the signed-in account.

A free session can read this help page. The tool card shows the name and the short summary. Opening the tool requires Pro.