Orifice plate sizing

DP Level & Flow

What this tool does

Bore and beta ratio for a given flow and differential pressure. This page says what the tool is for, in plain language. The working formula stays on the signed-in tool.

When to use it

Open Orifice plate sizing when this is the job: Bore and beta ratio for a given flow and differential pressure. That is usually a level or flow calibration, a bore check, or a valve you are about to size.

Step-by-step

  1. Open Orifice plate sizing from the tool list.
  2. Fill Fluid, Units, Volume flow, Pipe diameter from the instrument, the drawing, or the job record. Use the unit shown beside each field.
  3. Fill the remaining fields the same way. Skip a field only when the screen marks it optional.
  4. Run Calculate when that control is on the page, then read every result row and any warning.
  5. Check the result against the site procedure and the manufacturer data before you change a range, a wire, a setpoint, or a weight.
  6. This help page is public. Opening the tool still requires a Pro session.

Inputs

Fluid
Choose the Fluid that matches the instrument, the drawing, or the job. Choices include Liquid, Gas.
Units
Imperial or metric. Pick one and enter every other field in that system.
Volume flow
Volume flow is the value you read from the instrument, the drawing, or the job record. Enter it in gpm.
Pipe diameter
Pipe diameter is the value you read from the instrument, the drawing, or the job record. Enter it in in.
Differential pressure
Differential pressure is the value you read from the instrument, the drawing, or the job record. Enter it in inH2O.
Discharge coefficient
Discharge coefficient is the value you read from the instrument, the drawing, or the job record.
Density
Density is the value you read from the instrument, the drawing, or the job record. Enter it in lb/ft³.
Isentropic exponent
Isentropic exponent is the value you read from the instrument, the drawing, or the job record.
Upstream absolute pressure
Upstream absolute pressure is the value you read from the instrument, the drawing, or the job record. Enter it in psia.

Results

Result
The reported value for Orifice plate sizing. Use the unit printed on that row.
Warnings
A warning means an entry is incomplete or outside what this tool will stand behind. Recheck the inputs and the site procedure.

Common mistakes

  • Using the wrong specific gravity, or forgetting a wet leg, a seal fill, or a blanket pressure.
  • Mixing a head unit with a pressure unit without reading the unit on the screen.
  • Sizing from a flow or a differential that is not the one in the line.
  • Do not treat a result from Orifice plate sizing as a substitute for the site procedure or the manufacturer data.

Standards references

These are the standards and public references named on this tool. Clause numbers appear only when the catalog already cites them.

  • ISO 5167-1 mass-flow equation
  • ISO 5167-2 orifice limits and expansibility

Offline and access

This engine can run offline after the server has cached it for the signed-in account.

A free session can read this help page. The tool card shows the name and the short summary. Opening the tool requires Pro.

Help index

MileThree I&E Services